BS
24. August 2023
F-1
24. August 2023Test system for high-voltage cables up to 220kV rated voltage
Properties | Compact, easily transportable, versatile, PRPDA sample IEEE-compliant operating and safety devices, socket and fault location |
---|---|
DAC frequency range | 30 – 500 Hz |
Max. Output voltage | 288 kV |
Supply voltage | 3-phase 380 / 400V; 4kVA |
TE Resolution | 1 pC |
Standard | Cable testing according to IEC 60270, IEC 60060-3 |